Page 7 - Durapac_2016
P. 7
MASTER
WWW.DURAPAC.COM sync SYNCHRONOUS LIFT SYSTEM
EMERGENCY STOP PLC AND JOYSTICk RECESSED
located in prime location inside the frame to avoid accidental damage a
above touch screen and inclined to allow ease of operation
TOUCh SCREEN
POWER INDICATORS ON PLC
contained within own control box
and control panel boxes
PLC CONTROL BOX AND JOYSTICk EXTERNAL USB PORT
able to be removed and used up allows data to be downloaded for
to 5 metres from SyncMaster further analysis and record keeping
OIL LEvEL & TEMPERATURE SPECIALTY LIFTING SYSTEMS
alarms are displayed on touchscreen
DATA CABLE STORAGE REEL
with removable handle
RIGID STEEL FRAME
DATA CABLES
made from 50mm rolled hollow
use military and DIN fittings section (RHS) for extra strength
CONTROL vALvES POWDER COATED
high cycle, high speed solenoid components enhance the
valves allow precise flow control appearance and reduce corrosion
hYDRAULIC OUTLETS
eight outlets to control either LIFTING POINTS
single or double acting cylinders
for forklift
LOCkABLE LIFTING POINTS
for security for sling use
SELF CONTAINED
for ease of transport
WEAThER RESISTANT
EXTERNAL COvERS
for field conditions
are easily removed
hYDRAULIC hOSES
and data cables can be left connected
even when covers are attached 300 L
usable oil capacity with return line filter
DSM4038 - System Specifications Standard Inclusions Optional Items
Flow Rate 0.5-2.4 Lpm • Module system standard with 8 • Externally mounted stroke encoder
Pressure Rating 700 bar lifting points • Internally mounted stroke encoder
• Pressure transducers • Dual encoder inputs per lift point
Motor Size 4.0 kW • Analogue pressure gauge
Amps 8.85 • Adjustable pressure relief valves (Adv. & Ret)
• Oil temperature alarm
Hydraulic Outlets 8 x A & B ports • Oil filter alarm
Usable Oil Capacity 300 L • Emergency stop
• 15" full colour touch screen
Weight (Dry) 600 kg
• Flow control valves
Dimensions (mm) 1120 W x 1210 L x 1350 H
7